S
et-up and Programming
System set-up, voice recording, and
programming is accomplished via an
external touch tone phone which plugs
into a standard phone jack on the sys-
tem’s front panel.The user simply fol-
lows voice instructions given over the
phone.
System Controls
System operating status is provided
by front panel LED indicators. System
off/disarm ready controls are provided
on front panel. Surge protection and
noise suppression are standard.
A Truly Modern Autodialer
GUARD-IT fills the requirement
of a modern autodialerit should
be extremely reliable and be able to
tell the called party as much informa-
tion about the nature of an alarm as
possible so that the right personnel
can respond quickly and appropriately.
Many other autodialers don’t meet
these requirements.
Compare GUARD-IT with all the
others and you will see that this multi-
featured system offers a way to get
RACO flexibility, quality, and depend-
ability at a price you’d expect to pay
for one of the budget models.
Specifications
ELECTRICAL
Power Requirements: User supplied
10-14 VDC, 500 mA max.
Power consumption:
200 mA minimum standby
500 mA maximum active
Power failure: Automatic alarm
for external power failure.
Battery Charging: Precision voltage
controlled, automatic rapid recharge
after drain.
Universal Signal Inputs:
Digital Inputs; open contacts see
5VDC, closed contacts see 5 mA DC
For ordering information,
call toll free at… 800-722-6999
GUARD
IT
Analog Inputs; 4-20 mA, single ended.
Maximum voltage drop VDC.
Resolution 0.2%; absolute accuracy 0.5%
Local Alarm Relay: Transistor
output for TTL or relay drive
(500 mA 24 VDC max) activated
during unacknowledged alarm.
RJ11 Telephone line jack for connec-
tion to public telephone netowork.
PHYSICAL
Surge protection: Solid state protec-
tors on phone, power, and signal lines.
Enclosure: Single circuit card in dur-
able steel cabinet designed for mount-
ing on control panel wall or flush
mounted inside a larger control panel
with faceplate visible.
Weight:
4 pounds, 6 pounds with battery
Dimensions: 6.85"Hx8.85"Wx2.85"D
Mounting Centers: 3.6"Hx9"W
ENVIRONMENTAL
Temperature range: 20
°
to 130
°
F.
Humidity: 0 to 95%, noncondensing.
TELEPHONE
Rotary pulse or tone dialing.
Dials up to 8 different numbers, each
up to 60 digits long.
Time between alarm phone calls pro-
grammable 0.1 to 99.9 minutes.
Smart calling call progress monitoring
detects dial tone, basic ringback and
busy signal.
Alarm acknowledgement by touch tone
key or callback.
Compatible with most pager, cellular,
and voicemail systems.
User-furnished standard touch tone
handset required for programming.
FCC Registered.
PROGRAMMING
Standard phone jack on front panel
for programming phone. Voice menu
instructions guide programming.
SPEECH MESSAGES
User digitally records five messages,
Station ID and four channel alarm
messages. High definition digital
re-
cordings up to 12 seconds per message.
Resident synthesized voice vocabulary
for programming guidance.
FACTORY OPTIONS
Power Supply, UL Class 2 120 VAC
50/60 Hz adaptor.
Battery backup, internal 6 volt; 4 AH
gel cell provides 20 hours operation
during power failure.
NEMA 4X enclosure.
Cellularm cellular communication
system.
WARRANTY
Two year parts and labor warranty.
See separate warranty card for details.
Specifications subject to change.
© Copyright 1996 Raco Manufacturing and Engineering Co. #155 3M 9/04 Printed in USA
RACO MANUFACTURING
AND ENGINEERING, CO.
1400 62nd Street, Emeryville, CA 94608
Phone: (510) 658-6713
1-800-722-6999
Fax: (510) 658-3153
Web: www.racoman.com
Seitenansicht 1
1 2 3 4 5 6 7 ... 14 15

Kommentare zu diesen Handbüchern

Keine Kommentare